The calculation formula of the critical oxygen deficit model:
\( L=L_0exp(-k_dt) \)
\( O=O_s - \frac {k_dL_0}{k_a-k_d}[exp(-k_dt)-exp(-k_at)]-D_0exp(-k_at) \)
L——BOD concentration in river water, mg/L
Kd——the organic matter degradation constant, d-
Ka——Atmospheric oxygen-rich Changshu, d-
t - time, s
Os - saturated dissolved oxygen concentration in water, mg / L
Input data:
Kd—organic degradation constant, d: 40
Ka—Atmospheric oxygen rich constant, d: 30
T-time, s: 20
Os - saturated dissolved oxygen concentration in water, mg / L: 10
L0—the first stage BOD concentration, mg/L: 20
Do—dissolved oxygen, mg/L: 8
Click "Calculate" to output data
Critical oxygen deficit value: 10